42 liyy Vogtländisches Kabelwerk GmbH • Breitscheidstr. 122 • 08525 Plauen • Germany Phone: +49 3741 590-0 • Fax: +49 3741 590-270 • E-mail: [email protected] • Internet: www.voka.de

http://www.voka.de/upload/3_produktkatalog/04_Elektronik-Steuerleitungen/04_Eletronik-Steuerleitungen_PB_PDF/eng/LiYY_eng.pdf

Date added: October 22, 2014 - Views: 1

pdf
German DIN VDE Standards - BATT

DIN VDE 0812 Equipment wires and stranded equipment wires of telecommunications systems DIN VDE 0813 Switchboard cables for telecommunications systems DIN VDE 0814 Cords for telecommunications systems DIN VDE 0815 Wiring cables for teleco mmunications systems ( indoor cable)

http://www.batt.co.uk/upload/files/din_copy2.pdf

Date added: February 27, 2012 - Views: 356

pdf
Installation Cables - Maryland Metrics

tion to DIN VDE 0812 –Temperature range flexing – 58Cto+708C fixed installation –308Cto+708C – Electrical characteristics conductor resistance at 208C cond. 1 single- multi- nominal test + core core voltage volt-cores 1 Ohm/ Ohm/ age a.c., 50 Hz

http://mdmetric.com/prod/helukabel/L.Installation%20Cables.pdf

Date added: January 30, 2012 - Views: 17

pdf
SERVO MOTOR CABLES - SAB North America - Providing the best ...

Conductor: bare copper strands acc. to DIN VDE 0812 Insulation: TPE 510 Color code: colored Stranding: in layers or pairwise acc. to dimension: Screen: pairs screened or wrapped with tinned copper braid Inner jacket: TPE 510 over screened pairs

http://www.sabcable.com/new_data/SL843C.pdf

Date added: January 16, 2013 - Views: 2

pdf
HALOJENSÝZ SÝNYAL VE KONTROL KABLOLARI LÝHCH TSEK HALOGEN ...

(vde 0812-vde 0814-vde 0245) ( emc*) application:-indoor environments intensely populated by people where there is electromagnetic interference. 1-2-3-4-5-6-instrumentation and control engineering industrial electronics computers and office machines

http://www.kaztechno.com/docs/Cables/Erse/LIHCH.pdf

Date added: July 17, 2014 - Views: 1

pdf
LiYCY Multiconductor signal and control cable overall braid ...

with reference to DIN VDE 0812 Insulation: PVC, YI2 acc. to DIN VDE 0207 part 4 Color code: with reference to DIN 47100 Stranding ... PVC, YM1 acc. to DIN VDE 0207 part 5 Jacket color: gray LiYCY is a shielded, multiconductor signal and control cable recommended for use in European designed ...

http://www.sabcable.com/new_data/LiYCY.pdf

Date added: January 12, 2012 - Views: 21

pdf
VDE Prüf- und Zertifizierungsinstitut

Electrical characteristics as LIYCY acc. to DIN VDE 0812, table 4 mutual capacitance max. 120 nF/km (cores in pair formation ) Verwendungsbereich wie LIYCY, als Schaltkabel für Fernmelde- und Informationsverarbeitungsanlagen

http://www.ersekablo.com.tr/Assets/Documents/LIYCY-TP-VDE.pdf

Date added: October 22, 2014 - Views: 1

pdf
Applications: RoHS Braided shielded LiYCY cables for data ...

Applications: Braided shielded LiYCY cables for data transmission and electronics according to VDE 0812 / VDE 0207 standards. Characteristics: Conductors: stranded in O.F.C. red copper

http://www.italsurplus.com/tasker/taskercatalogue%20135.pdf

Date added: September 10, 2013 - Views: 6

pdf
PVC YALITIMLI SÝNYAL VE KONTROL KABLOLARI LÝYY TSEK PVC ...

b-01 pvc yalitimli sÝnyal ve kontrol kablolari (vde 0812-vde 0814-vde 0245) pvc insulated signal and control cables application: 1-2-3-4-5-6-note:

http://www.kaztechno.com/docs/Cables/Erse/LIYY.pdf

Date added: October 22, 2014 - Views: 1

pdf
LiYY - TFKable

LiYY DIN VDE 0812 TELE-FONIKA Kable Sp. z o.o. S.K.A. www.tfkable.com Flexible PVC control cables for electronics CONSTRUCTION Conductors bare copper, fine wire conductors, bunch stranded

http://www.tfkable.com/sites/default/files/karty-katalogowe/ttm-0005_liyy_eng.pdf

Date added: May 22, 2013 - Views: 31

pdf
the case of fire for telecommunication and data processing ...

nach DIN VDE 0812 Verseilung: Typ: LIHCH, adrig verseilt Typ: LIHCH-TP, paarig verseilt Schirm, Geflecht nach DIN VDE 0812, Abschnitt 5.1.3 Mantel, halogenfreie Mantelmischung nach DIN EN 50290-2-27 höchste Temperatur am Kabel 70 °C Mantelfarbe grau

http://www.ersekablo.com.tr/Assets/Documents/LIHCH-TP-VDE.pdf

Date added: October 22, 2014 - Views: 1

pdf
Industrial Ethernet Cables CAT 5 / CAT 6 - SAB Cable

Industrial Ethernet is a young and quickly developing network technology. Ethernet with the worldwide accepted TCP/IP (Transmission Control Protocol/Internet Protocol) ... core-ø ± 5% figure weight at 20°C acc. to VDE 0812

http://www.sab-cable.com/fileadmin/user_upload/pdf/catalog_gb/Leitungen_gb/Industrial_Ethernet_Cables_CAT5_CAT6.pdf

Date added: May 4, 2013 - Views: 10

pdf
Suggested Copy for Lapp Cable in CPC Catalogue

similar to VDE 0812. Design Conductor fine-wire strands of bare copper wire; 0.14 mm2 to 1.5 mm2 , 7-wired ... Flame propagation flame retardant to VDE 0482, part 265-2-1/IEC 60 332-1 *) valid for 4 pairs and more **) values for f: ...

http://www.farnell.com/datasheets/45143.pdf

Date added: October 11, 2012 - Views: 4

pdf
LiYY PVC Data Cable - Caledonian Cables

German Standard (VDE) LiYY PVC Data Cable Application and Description LiYY cables are data transmission cables which have been developed from well proven types based on the specification VDE 0812. For use in flexible or stationary applications under low mechanical stress with free

http://www.caledonian-cables.net/product/industrial_cables/LiYY_PVC_Data_Cable.pdf

Date added: May 31, 2012 - Views: 34

pdf
the case of fire for telecommunication and data processing ...

und Informationsverarbeitungsanlagen mit verbessertem Verhalten im Brandfall und Isolationserhalt. Guide to use acc. to DIN VDE 0812 clause 1, as

http://www.orenkablo.com/kalitebelgeleri/vde/LIHCH-vde-belgesi.pdf

Date added: August 25, 2013 - Views: 4

pdf
RoHS Braided shielded LiYCY cables for data Conformity VDE ...

Applications: Braided shielded LiYCY cables for data transmission and electronics according to VDE 0812 / VDE 0207 standards. Characteristics:

http://www.tasker.it/include/down_pdf.php?f=1058&n=C211_DataSheet

Date added: February 15, 2014 - Views: 1

pdf
~HI-TECH I www. h itech controls .com CONTROLS, INC. Click or ...

Cables according to VDE 0812 Technical data YR-Bell Sheathed Cables • Adapted to DIN VDE 0812 • Minimum bending radius 15x cable 0 YV-Equlpment Wires • Equipment wires with PVC core insulation to DIN VDE 0812 • Temperature range ...

http://www.hitechcontrols.com/pdf_cable/O-installation-cables.pdf

Date added: May 22, 2013 - Views: 1

pdf
LiY (LiYv) VDE single-core - Mueller Group

VDE single-core LiY (LiYv) is a 80 Deg. C. flexible VDE approved PVC hook-up wire recommended for the connection of low voltage ... - VDE-0812 - CE Low Voltage Directive 73/23/EEC and 93/68/EEC - ROHS compliant Color Code Chart 00 - Green/Yellow 01 ...

http://www.muellergroup.net/har-lead/330-LIY.pdf

Date added: June 12, 2013 - Views: 8

pdf
RoHS Braided shielded LiYCY cables for data Conformity VDE ...

Applications: Braided shielded LiYCY cables for data transmission and electronics according to VDE 0812 / VDE 0207 standards. Characteristics: Conductors: stranded in O.F.C. red copper

http://www.tasker.it/include/down_pdf.php?f=368&n=C215_DataSheet

Date added: January 14, 2014 - Views: 1

pdf
I Click or Call for a Quotel - Hi-Tech Controls

DIN VDE 0812 • Core colours see below www. h itech controls .com Properties • PVC self-extinguishing and flame retardant according to VDE 0482-332-1-2, DIN EN 60332-1-2/ IEC 60332-1 (eQuivalent DIN VDE 0472 part 804 test method Bl

http://www.hitechcontrols.com/pdf_cable/K-Single_Conductors.pdf

Date added: May 28, 2013 - Views: 2

pdf
KAT0812-0002-E Insulated Conductor Rail SinglePowerLine 0812

The SinglePowerLine 0812 conductor rail system is used as a standard product to power bridge, portal and process cranes, ... VDE 0110-1:2008-1 Insulation coordination for electrical equipment in low-voltage installations - Part 1: Principles, requirements and testing (IEC

http://www.conductix.com/sites/default/files/downloads/KAT0812-0002-E_Insulated_Conductor_Rail_SinglePowerLine_0812.pdf

Date added: November 6, 2013 - Views: 4

pdf
HSLCH-JZ,OZ 300/500V - TFKable

HSLCH-JZ,OZ 300/500V ZN-TF-201; DIN VDE 0812/ HD 21.1 TT1-6498 17.04.2014 TELE-FONIKA Kable S.A. www.tfkable.com LSOH insulated and LSOH sheathed

http://www.tfkable.com/sites/default/files/karty-katalogowe/tt1-6498_hslch-jz_-oz.pdf

Date added: June 3, 2014 - Views: 1

pdf
LiY / LiYv / LiYv-t - Caledonian Cables

VDE 0812, CE Low Voltage Directive 73/23/EEC and 93/68/EEC, ROHS compliant Cable Construction ... - Static temperature: -30º C to +80º C(temporary 105 º C for LiYv-t) - Flame retardant: VDE 0472 part 804, test method B, and IEC 60332.1 - Insulation resistance: 10 MΩ x km Cable Parameter AWG

http://www.caledonian-cables.net/product/industrial_cables/LiY-LiYv-LiYv-t.pdf

Date added: January 26, 2013 - Views: 8

pdf
LiYv-t VDE single-core +105 Deg C. - Mueller Group

VDE single-core +105 Deg C. LiYv-t is a 105 Deg. C. flexible VDE approved improved heat resistant PVC hook-up wire recommended for the ... - VDE-0812 - CE Low Voltage Directive 73/23/EEC and 93/68/EEC - ROHS compliant Color Code Chart 00 - Green/Yellow 01 ...

http://www.muellergroup.net/har-lead/334-LiYv-t.pdf

Date added: June 21, 2013 - Views: 4

pdf
TP SHIELDED COMPUTER & CONTROL CABLES MULTI-PAIR (VDE 0812,0814)

SHIELDED COMPUTER & CONTROL CABLES MULTI-PAIR(VDE 0812,0814) † Construction-Multi wire copper conductor.-Insulation PVC. (YI1) Colour codes according to DIN 47100.

http://en.emekkablo.com/Admin/Images/Document/1263797765_5-_LiYCY(TP).pdf

Date added: August 25, 2013 - Views: 1

pdf
Certificate of compliance with the order 2.1 according HELUKABEL

LiY We confirm that the above mentioned, PVC single cores are produced according to DIN VDE 0812 and tested to DIN VDE 0472/0473. -Temperature range

http://www.helusta.lt/media/file/LiY%20sertifikatas.pdf

Date added: May 22, 2013 - Views: 3

pdf
PAAR-TRONIC-CY-CY (LiYCY-CY) - HELUKABEL

DIN VDE 0812 ÀSpecial PVC data transmission cable ... DIN VDE 0207 part 4 ÀThe materials used in manufacture are ÀCore colours to DIN 47100 with colour cadmium-free and contain no silicone and repetition ÀNominal voltage 0,14 mm² = max. 350 V

http://www.helukabel.de/pdf/ks/1KS_21065_en.pdf

Date added: March 7, 2014 - Views: 1

pdf
YV-Equipment Wires / YR-Bell Sheathed Cables according to VDE ...

YV-Equipment Wires / YR-Bell Sheathed Cables according to VDE 0812 Properties YV-Equipment Wires Cable structure YV-Equipment Wires Technical data YR-Bell Sheathed Cables

http://www.urkunde.es/pdf/helukabel/chapter_O_Infrastructure_Cables_and_Wires/O%20%20005%20YV-Equipment%20Wires%20YR-Bell%20Sheathed%20Cables.pdf

Date added: October 22, 2014 - Views: 1

pdf
Infrastructure Cables and Wires

YV-Equipment Wires / YR-Bell Sheathed Cables according to VDE 0812 Cable structure Properties YV-Equipment Wires Technical data YR-Bell Sheathed Cables YV-Equipment Wires

http://www.metricate.org/prod/helukabel/535_helukabel_CABLES-WIRES_2012-2013.pdf

Date added: October 22, 2014 - Views: 1

pdf
type of conductor cross section manufacturer/supplier ...

LiY 1,5 mm² Westadraht PVC VDE 0812 LiY 0,5 mm² Westadraht PVC VDE 0812 H05V-K 1 mm² XBK-Kabel PVC DIN VDE 0281 T.3 H05V-K 0,75 mm² XBK-Kabel PVC DIN VDE 0281 T.3 H05V-K 0,5 mm² XBK-Kabel PVC DIN VDE 0281 T.3 H05V-U 1 mm² XBK-Kabel PVC --

http://www.ab.com/industrialcontrols/products/terminal_blocks_and_wiring/iec/pdf/Tested_Wires_K2.pdf

Date added: November 15, 2011 - Views: 21

pdf
SERVO CABLES GAALFLEX SERVO T 807 C - Elettrotek Kabel

162 SERVO CABLES Construction: Features: Technical data: Conductor:bare copper strands acc. to DIN VDE 0812 Insulation:PE L/MD acc. to DIN VDE 0819 part. 103

http://www.elettrotekkabel.com/allegati/elettrotekkabelcatalog/GAALFLEX%20SERVO%20T%20807%20C.pdf

Date added: December 17, 2013 - Views: 1

pdf
PROFIBUS-DP CABLES - Elettrotek Kabel

www.elettrotekkabel.com 198 PROFIBUS-DP CABLES Construction: Construction: Technical data: Technical data: Conductor: 20,34 mm : Stranded red copper conductor acc. to DIN VDE 0812

http://www.elettrotekkabel.com/allegati/elettrotekkabelcatalog/SPECIAL%20PROFIBUS%20634%20634%20UL.pdf

Date added: December 19, 2013 - Views: 1

pdf
E Bus int Layout 1 - SAB Cable

acc. to VDE 0812 tinned copper strands, extra fine wires Core insulation: PE, L/MD acc. to DIN VDE 0819 part 103 PE PE, L/MD acc. to DIN VDE 0819 part 103 PE Colour code: blue, yellow, white, orange Stranding: in layers Wrapping: PETP foil

http://www.sab-cable.com/fileadmin/user_upload/pdf/catalog_gb/kapitel_E/E_en_27.pdf

Date added: August 6, 2014 - Views: 12

pdf
ÖLFLEX - Maryland Metrics

LiF Stranded core to VDE 0812, superfine wire 4. Special features T Support wire Ö Enhanced oil resistance U Flame-retardant w Heat resistant, weather resistant FE Insulation retained for a limited time C Screen braiding D Screening as envelope

http://mdmetric.com/elect/T6_Type_Abbreviations.pdf

Date added: October 11, 2012 - Views: 4

pdf
INDUSTRIAL ETHERNET CABLE CAT. 5 - Elettrotek Kabel

Flexibleacc. to VDE 0812 Insulation:PE type L/MD acc. to DIN VDE 0819 part 103 Colour cores: blue, yellow, white, orange Stranding: (PROFINET 662 and 663 PLTC): cores twisted in pairs, pairs twisted together (PROFINET 663): in layers (star-quad construction)

http://www.elettrotekkabel.it/allegati/elettrotekkabelcatalog/PROFINET%20662%20663%20663%20PLTC.pdf

Date added: February 15, 2014 - Views: 1

pdf
LiY, LiYV, LiYv-t - KENEX

LiY tio DIN VDE 0812, flexible hook-up wire of PVC. PVC insulated flexible hook-up wires are used for the connection for low voltage applications, communication apparatus, electronik assemblies and equipment, racks,

http://www.kenex.de/pdf/PVC-Kabel/S162-163_LiY_LiYV_LiYv-t.pdf

Date added: February 26, 2012 - Views: 10

pdf
German DIN VDE Standards - BATT

DIN VDE 0812 Equipment wires and stranded equipment wires of telecommunications systems DIN VDE 0813 Switchboard cables for telecommunications systems DIN VDE 0814 Cords for telecommunications systems DIN VDE 0815 Wiring cables for telecommunications systems ( indoor cable)

http://www.batt.co.uk/upload/files/din_copy1.pdf

Date added: September 26, 2012 - Views: 90

pdf
ÖLFLEX - SP Prod

VDE 0281/0282 VDE 0812 Specific insulation resistance > 20 GOhm x cm Inductivity Approx 0.7 mH/km Conductor stranding Fine wire or superfine wire Torsion Torsion load max. Without screening: +/- 360° /m with screen-ing (DP) +/- 180°/m Minimum bending radius

http://mtron.spprod.com/country/3/external/pdf/pg_0132_HK2010_en_OLFLEX_ROBOT_900_DP.pdf

Date added: July 8, 2014 - Views: 1

pdf
R-Bandleıtung -Flat-Rıbbon-Cable

Aufbau Leiter: Kupfer-Litze, verzinnt, Isolation: PVC nach VDE 0207 Yl 2 oder Yl 8 Farbe: Farbfolge nach DIN 47100 und VDE 0812 oder einfarbig mit

http://www.bekon.de/pdf/pdf/band/band4.pdf

Date added: September 17, 2014 - Views: 1

pdf
Reference to DIN VDE Standards - HELUKABEL

Reference to DIN VDE Standards Power Installations • DIN VDE 0100 – Erection of power installations with rated voltages below 1000 ... • DIN VDE 0812 – Equipment wires and stranded equipment wires of telecommunications system

http://www.helukabel.de/media/publication/de/cor_docs/qt_23/QT_COR-DOCS_X_005-006_Reference_to_DIN_VDE_Standards.pdf

Date added: January 26, 2013 - Views: 12

pdf
DEUTSCHE NORM November 1988 Schaltdrähte und Schaltlitzen ...

Seite 2 DIN VDE 0812 1 Anwendungsbereich Diese Norm gilt für PVC-isolierte Schaltdrähte und Schaltlitzen, die für die Verdrahtung von Fernmeldegerä-

http://www.dlqyw.net/down/soft/标准共享/国际标准/DIN%20VDE%200812:1988%20通讯及数据传输用电缆.pdf

Date added: January 20, 2014 - Views: 1

pdf
INDUSTRIAL ETHERNET CABLE CAT. 5 - Home Page - Elettrotek Kabel

fine wires acc. to DIN VDE 0812 Insulation: PE type L/MD acc. to DIN VDE 0819 part 103 Cores color: blue, yellow, white, orange Stranding: in layers Wrapping: PETP foil Inner sheath: thermoplastic compound Screen: Flexiblealuminium tape and tinned copper braid

http://www.elettrotekkabel.it/allegati/elettrotekkabelcatalog/_PROFINET%20654%20655%20660%20661.pdf

Date added: December 4, 2013 - Views: 1

pdf
LiYCY - megawatt

ðñïäéáãñáöÝò VDE 0812. ÊÁÔÁÓÊÅÕÇ • Áãùãïß: Ëåðôïðïëýêëùíá óõñìáôßäéá ÷áëêïý (VDE 0295 Class 5) 0.34 mm2 åðôÜêëùíá ...

http://www.megawatt.com.gr/files/uploads/LiYCY.pdf

Date added: August 11, 2014 - Views: 1

pdf
LiYCY - Elektrometal

LiYCY Standard: VDE 0812 Construction: Cu, fine stranded, insulation/sheath Cu-braided screen Aplication: Screened flexible control and instrumentation cable for low power

http://www.el-metal.net/images/uploads//LiYCY%20eng.pdf

Date added: October 22, 2014 - Views: 1

pdf
VDE 0812 • DIN 47100 Nº Cond. x Secção Code Ar Nº ...

Código Ar go Code Ar cle Part Number Nº Cond. x Secção Nº Cond. x Seccion Nº Cond. x Cross Sec on Diâmetro Diametre Diameter Peso do Cobre

http://www.policabos.pt/fotos/editor2/Cap2%20POLISCREEN.pdf

Date added: April 16, 2013 - Views: 5

pdf
VDE Priif- und Zertifizierungsinstitut - Sami

VDE Priif- und Zertifizierungsinstitut GUTACHTEN MIT FERTIGUNGSOSERWACHUNG CERTIFICA TE OF CONFORMITY WITH FACTORY SURVBLUtNCE ... DIN VDe 0812:1988.11 (in Anlehnung anfwith reference ta) Sefristet zum I valid unti!: 2010~12-31 Aktenzeichen: 1765800-5320-0021 I 96227

http://www.sami.it/sito/pdf/certificazioni/VDE-7633-tpr.pdf

Date added: May 31, 2012 - Views: 6

pdf
LiHCH Гъвкави Стандарт: VDE 0812 , Cu

lihch Гъвкави кабели за индустриална електроника Стандарт: vde 0812 безхалогенна изолация и обвивка

http://www.elgrup.net/Portals/0/kabeli_i_provodnici/komunikac_kabeli_provodnici/gavkavi_upravlenie_kontrol/5.pdf

Date added: May 22, 2013 - Views: 3

pdf
LiYCY (TP) - Elektrometal

LiYCY (TP) Standard: VDE 0812 Construction: Cu, fine stranded, insulation/sheath Cu -braided screen, cores twisted into pairs Aplication: Screened flexible control and instrumentation cable for low power

http://www.el-metal.net/images/uploads//LiYCY%20TP%20eng.pdf

Date added: October 22, 2014 - Views: 1

pdf
LIY - 株式会社ケーメックス

Based on VDE 0812 Product make-up Stranded copper wire Core insulation: PVC-based YI 2/TI 2 acc. VDE 0207-4 Labelled with coloured stripes Technical data Peak operating voltage 900 V (0.25 sq.mm) Conductor stranding

http://www.kmecs.com/technical_info/download.php?id=543

Date added: August 8, 2014 - Views: 1

pdf
LiYY pairs, So-LiYY pairs, - Novkabel

LiYY pairs, So-LiYY pairs, Standard: VDE 0812; PSN 08 C010 Nominal voltage: 250 V 1500 V CONSTRUCTION Conductor: Bare or tin-plated wire strands. Insulation: PVC mixture.

http://www.novkabel.com/artikal/143_en.pdf

Date added: December 4, 2013 - Views: 1